R32 refrigerant, inverter compressors, and denser outdoor-unit packaging are pushing capacitor operating temperatures beyond what 70°C-rated parts can sustain. In response, distributors and serv...
belajar lagi Kapasitor starter CD60 digunakan terutamanya untuk permulaan motor tork yang tinggi, seperti penyaman udara dan pemampat beku, pam air, atau sistem bekalan kuasa tunggal fasa lain yang tidak disengajakan dan motor asynchronous tiga fasa menggunakan bekalan kuasa fasa tunggal.
| Kapasitansi | 110v | 125v | 160v | 220v | 250v | 300v | 330v |
| 50 | 34*60 | 34*60 | 34*70 | 34*80 | 34*80 | 34*80 | 42*80 |
| 75 | 34*60 | 34*70 | 34*70 | 34*80 | 42*80 | 42*80 | 42*80 |
| 100 | 34*70 | 37*70 | 38*80 | 34*80 | 42*80 | 42*80 | 45*90 |
| 150 | 34*70 | 34*80 | 38*80 | 42*80 | 42*80 | 45*90 | 45*90 |
| 200 | 34*80 | 34*80 | 42*80 | 42*80 | 45*90 | 45*90 | 45*100 |
| 250 | 34*80 | 34*80 | 42*80 | 45*90 | 45*90 | 45*100 | 45*100 |
| 300 | 42*80 | 42*80 | 45*90 | 45*90 | 50*100 | 50*100 | 50*100 |
| 350 | 42*80 | 42*80 | 45*90 | 45*100 | 50*100 | 50*110 | 50*110 |
| 400 | 45*90 | 45*90 | 45*100 | 45*100 | 50*100 | 50*110 | 50*110 |
| 500 | 45*90 | 45*90 | 45*100 | 50*100 | 50*100 | 50*110 | 50*110 |
| 600 | 45*90 | 45*100 | 50*100 | 50*100 | 50*1 10 | 50*110 | 50*110 |
| 7000 | 50*90 | 50*100 | 50*110 | 50*110 | 50*110 | 50*110 | 63*110 |
| 800 | 50*100 | 50*110 | 50*110 | 50*110 | 50*110 | 63*110 | |
| 1000 | 50*100 | 50*110 | 50*110 | 50*110 | 63*110 | ||
| 1200 | 50*110 | 50*110 | 63*110 | 63*110 | |||
| 1500 | 63*110 | 63*110 | 63*110 |
| Model | Kapasitansi μf | Voltan V | D | L. |
| SPP4A | 88-106 | 90-130 | 36.5 | 122 |
| Spp5b | 43-52 | 90-227 | 36.5 | 122 |
| Spp6b | 88-106 | 90-227 | 46 | 118 |
| Spp7b | 130-156 | 90-227 | 46 | 142 |
| SPP7c | 130-156 | 90-227 | 46 | 142 |
| SPP8B | 145-174 | 90-227 | 46 | 142 |
| SPP8C | 145-174 | 90-227 | 46 | 142 |
| Spp5 | 36-77 | 115-288 | 46 | 130 |
| SPP6 | 76-130 | 115-288 | 46 | 155 |
| SPP7 | 130-227 | 115-288 | 46 | 155 |
| Parameter teknikal | Nilai rujukan | |
| Julat voltan | 110VAC ~ 330VAC 50/60Hz | |
| Julat kapasitans | 20μ f ~ 1 500μF | |
| Toleransi kapasitans | ± 10% (k), ± 20% (m) | |
| Julat suhu operasi | -20 ℃ ~ 65 ℃ | |
| Menahan voltan | T-t | -20C ~ 65C |
| T-C | 2un 1000VAC/10S (≥2000V) | |
| Faktor pelesapan | ≤0.15,100Hz, 20 ℃ | |
| Ketinggian | ≤2000m | |
| Standard rujukan | GB/T3667.2, IEC/EN60252.0, UL810 | |
R32 refrigerant, inverter compressors, and denser outdoor-unit packaging are pushing capacitor operating temperatures beyond what 70°C-rated parts can sustain. In response, distributors and serv...
belajar lagiA 35/5 MFD capacitor looks identical on the shelf. The one that fails after 14 months and the one that still reads within tolerance after seven summers are separated by things you cannot see fro...
belajar lagiAnyone who has watched a shared thermostat get bumped five degrees a dozen times a day knows the problem an Air Conditioner Parts Thermostat Guard solves. It's a protective enclo...